Laser beta lasermike LS8000-3 Manuale Utente

Pagina di 221
LaserSpeed 8000-3 Instruction Handbook
 
LaserTrak Software 
 
 
Part No. 93463 / Drawing No. 0921-01561 
Page 110 of 221 
Revision A (Sep 2007) 
m/min x 1min/60sec x 10,000 pulses/m = 166,667 1/s ).  The range is 0.001 to 
100,000. 
Measurement Units 
  
Sets the units that the length and speed will be measured in. Available choices 
are: 
• Feet/sec 
• Feet/minute 
• Meters/sec 
• Meters/min 
• Inches/min 
• Millimeters/min 
• Millimeters/sec 
• Yards/min 
• Yards/sec 
Length will be in m, feet, mm, in or yards, depending on the selected value. 
User Update Rate 
The core period determines how often the LaserSpeed sensors provide the 
LaserTrak software with an updated speed and length measurement. Available 
choices are Fast (4ms), Medium (32ms) and Slow (100ms) in the Standard 
settings.  For the advanced settings the available choices are 1 to 2000 ms in 
1 ms increments. 
The Recommended User Update Rate is 32 ms.  
 
Output Configuration Parameters 
Analog Zero Scale 
Sets the speed equal to the analog zero scale.  See the Analog Output Voltage 
Section for details. 
Analog Full Scale 
Sets the speed equal to the analog full scale.  See the Analog Output Voltage 
section for details. 
AFS Represents QF 
When checked the gauge will output QF on the analog output as a 0 to 1 volt 
signal. 0 - QF 0 and 1 volt –QF=15. When not checked the gauge will output 
speed on the analog output as a 0 to 2 volt signal   
Auxiliary Digital Output 
Func. 
Sets the operation of the Auxiliary output. The choices are show on the pop up 
menu. 
 
High Speed Pulse 
Config 
The high speed pulse output defaults to outputting pulse according to the High 
Speed Pulse Rate set in the standard Configuration Tab. The pulse output can 
be configured to output gauge status if the high speed pulse output is not 
needed. The choices are shown in drop down menu.