Laser beta lasermike LS8000-3 Manuale Utente

Pagina di 221
LaserSpeed 8000-3 Instruction Handbook
 
Appendix E: Troubleshooting Guide 
 
 
Part No. 93463 / Drawing No. 0921-01561 
Page 218 of 221 
Revision A (Sep 2007) 
 
 
 
Shutter Open 
 
 
 
 
Material Present 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
System Ready 
connected to User Ground (Pin 
11,19,21) for the laser to turn on.  Check 
wiring connections. 
 
The Laser Interlock (Pin 17) must be 
connected to User Ground (Pin 
11,19,21) for the laser to turn on.  Check 
wiring connections. 
 
Check setting in LaserTrak for 
Internal/External Material Present 
Internal:  Adjust Material Present 
threshold level until Material Present 
bit changes. 
External Active Low: Disconnect 
Material Present (Pin 10), or connect 
to User Ground to turn Material 
Present On, and Connect to +5-
24V
DC
 to turn Material Present Off. 
External Active High: Disconnect 
Material Present (Pin 10) to turn OFF 
Material Presnent, and connect to +5-
24V
DC
 to turn ON Material Present.  
Make sure you reference the voltage 
input to the User Ground (Pin 
11,19,21). 
 
System Ready bit is a combination of 
the Laser On, Shutter Open, and Laser 
At Temp status bits.  These three bits 
must all be ON for the System Ready bit 
to be on. 
 
Nothing illuminated on gauge (i.e. 
no LED lights, and laser is off) 
Loss of Power 
 
 
 
 
Power Supply Failure 
The POWER ON Led should always be 
illuminated when the gauge has power.  
Check electrical connections, fuses, and 
power switch 
 
1.  Check power supply voltage 
2.  Replace Power Supply 
 
 
Ethernet 
 
Can't get Ethernet to work. 
No Connection 
 
 
 
 
Gauge doesn't have 
Check the Link status light on the router 
to see if the connection is ok.  Set the 
gauge's COMM LED to indicate Ethernet 
traffic. 
 
Send the gauge the *ETHERNET?<CR>