LaserSpeed 8000-3 Instruction Handbook
 
Interfacing with the LS8000-3 
 
 
Part No. 93463 / Drawing No. 0921-01561 
Page 55 of 221 
Revision A (Sep 2007) 
 
Index (Printer) Pulse Output (Pins 22-23) 
Also referred to as a Once-Per-Rev (OPR) pulse, this output can be configured 
to output pulses at specified length intervals. This output can be used to 
control a cutter or a printer. 
For example, if you use LaserTrak to set the “Index Pulse Every X m” setting 
to 10m, the gauge would output a single pulse every 10m of product 
movement. 
The Index pulse will only trigger when the line is moving in the (+) direction.  If 
the Index Pulse triggers at a certain length, and then the line backs up and 
passes that point again, the Index Pulse will not be repeated. 
The Index Pulse is asserted for a configurable amount of time.  This time can 
be configured by changing the Index Pulse Length setting.  See the 
Configuration Settings
 section for details. 
Example
Index Pulse Length = 100ms 
Index Pulse Interval = 10m 
 
Index Pulse Output Example 
 
The Index Pulse Output can be reconfigured to output several different status 
outputs using the Auxiliary Digital Output Configuration setting.  See the 
Configuration Settings
 section for details. 
 
+24V
DC
 Power Input (Pins 24-25) and Power Grounds (Pins 12-13) 
Two Power Input pins and two Power Ground pins are supplied to reduce 
voltage drop in long cables.  Please see the Connecting Power to the Gauge 
section and Appendix D for details concerning power wiring.  Pins 24 and 25 
and pins 12 and 13 are internally connected in the LS8000-3.