Length Reset Input Circuit 
The Length Reset Input Action configuration setting affects how this input 
resets the length.  The input can be configured to reset the length on level and 
edges.  See the Length Reset Input Action command description in the 
Configuration Settings
 section for details. 
 
User V
IN
 (Pin 20) 
Voltage input for Isolated Pulse Outputs, and the Index Pulse Output.  
Connecting a voltage from 5-28VDC to this input allows you to control the 
pulse amplitude of the LS8000-3 Scaleable Pulse Outputs (Pins 15, 5, 6, 8), 
and the Index Pulse Output (Pins 22 and 23.)  The voltage supplied will be the 
voltage level of the pulse outputs supplied by the LS8000-3.  If a voltage is not 
supplied, the pulse outputs will be approximately 4.5V. 
 
Pulse Output
Internal Isolated +5V
Signal Ground
(Pins 11, 19, 21)
User V  (Pin 20)
IN
Pulse True
Pulse False
GND
User V
IN
GND
User V
IN
 
User V
IN
 Schematic