Application Interfaces 
Light Stack Interface 
The LS8000-3 User Scaleable Pulse Outputs and Index Pulse output can be 
reconfigured and connected to a light stack in order to indicate the current 
state of the laser in order to warn people in the area of laser radiation.  The 
pulse outputs can be reconfigured into a light stack interface by setting the 
following settings: 
 
Setting 
Value 
Command 
Index Pulse Output Function 
Light Stack (Green) 
#9<CR>
 
User Scaleable Pulse Output 
Configuration 
Light Stack (Yellow/Red) 
$L9<CR>
 
 
The outputs can then be connected to solid state relays in order to drive a light 
stack as shown below.  This will provide a contact closure for each lamp.  The 
maximum current that can be driven by this interface will depend on the 
selected relay.