Harris Performance 6800 Manuale Utente

Pagina di 76
 6800/7000 Series - Frames and Power Supplies Installation and Operation Manual
19
FR-6804(-1)/CF-6801 Installation
 Chapter 4: CF-6801 Cooling Frame
FR-6804(-1)/CF-6801 Installation
To properly install the CF-6801 with the FR-6804(-1), follow this 
procedure:
1. Mount the CF-6801 directly above the FR-6804(-1).
2. Attach the DC supply cable to the DC 3-pin connector at the back of 
the FR-6804(-1), following the labeled positions for positive, 
negative, and ground.
3. Attach the other end of the DC supply cable to the DC 5-pin 
connector at the back of the CF-6801 cooling frame, observing 
correct polarity. See Figure 4-3.
Figure 4-2. 
FR-6804(-1) and CF-6801 Connections
LEITCH
CF-6801
GND
V+
V-
GPI 1
GPI 2
MADE IN
CANADA
BLK
CLEAR
SHIELD
R
FR-6804
GND
NC
NO
GND
V+2
V-2
90-250VAC
270VA
50/60Hz
MADE IN CANADA