GSI Outdoors AUTOFLOW 2TF Manuale Utente

Pagina di 57
2000 Autoflow
37
POWER/MOTOR WIRING
          
The Following diagram details the configuration
for correct main power installation.   Use the diagram
in conjunction with the Electrical Load information and
Wire Size information provided.  The diagram details
the correct main power installation for 220V 1 ph, 230V
ph, 460V 3ph, 575V 3ph, and 380V 50hz power
supplies.
      On all three phase systems put the leg with the
highest potential difference between that leg and ground
( wild or high voltage leg) on the center terminal (L2)
at the motor starter.
NOTE: Standard electrical safety should be used.
(Refer to the National Electrical Code Standard
Handbook by the National Fire Protection
Association).  A qualified electrician should make
all electrical wiring installations.  Follow all local
or national electrical safety standards and
ordinances when installing the equipment.
Main Power Schematic