Electrical Load
Information
The following charts provide infor-
mation for the electrician wiring the
grain dryer, and are a reference
guide for parts. It is recommended
that you contact your local power
company and have a representatives
survey the installation to see that
your wiring is compatible with their
system and that adequate power is
supplied to your unit. Remember
that the only thing connected to the
recommended service amps should
be your grain dryer. Standard elec-
trical safety should be used. (Refer
to the National Electrical Code
Standard Handbook by the National
Fire Protection Association). A
qualified electrician should make all
electrical wiring installations.
Dryer Fan 
Size
Voltage
Horsepower
Full Load 
Amps
Motor 
Starter 
Relay 
Heater 
Strips
Fuse       
(Slow Blow)
Breaker
220v1ph
10-12
48
75
F614B
80
80
208v3ph
10-12
35
40
C400B
60
60
36"
220v3ph
10-12
33
40
C366B
60
60
380v50hz
10-12
15
30
C180B
30
30
460v3ph
10-12
17
30
C198B
30
30
575v3ph
10-12
15
30
C180B
30
30
220v1ph
10-16
78
90
F914B
100
100
208v3ph
15
44
60
C460B
60
60
36"
220v3ph
15
39
60
C400B
60
60
380v50hz
15
27
30
F772B
60
60
460v3ph
15
20
30
C228B
30
30
575v3ph
15
16
30
C198B
30
30
220v1ph
10-16
78
90
F914B
100
100
208v3ph
15
44
60
C460B
60
60
42"
220v3ph
15
39
60
C400B
60
60
380v50hz
15
27
30
F772B
60
60
460v3ph
15
20
30
C228B
30
30
575v3ph
15
16
30
C198B
30
30
208v3ph
20
61
75
F772B
80
80
220v3ph
20
50
60
C500B
80
80
42"
380v50hz
20
32
40
C366B
60
60
460v3ph
20
25
30
C303B
40
40
575v3ph
20
20
30
C228B
40
40
208v3ph
30
80
90
F104C
150
150
220v3ph
30
74
75
F772B
150
150
42"
380v50hz
30
39
40
C440B
80
80
460v3ph
30
37
40
C400B
80
80
575v3ph
30
30
40
C330B
80
80
208v3ph
40
108
120
F118C
200
200
220v3ph
40
102
120
F118C
200
200
42"
380v50hz
40
47
60
C500B
100
100
460v3ph
40
51
60
C550B
100
100
575v3ph
40
40
60
C400B
100
100
ELECTRICAL POWER SUPPLY