Elmo Server 1.3 Manuale Utente

Pagina di 74
A.7.1 
Auxiliary Supply  
Feature Details 
Auxiliary power supply  
DC source only 
Auxiliary supply input voltage  
24 V +15%  
Auxiliary supply input power 
20 W 
  The Tuba CANNOT operate without a 24 Volt Auxiliary Power Supply  
  Be sure to maintain power within the 24 V +15% range as higher voltages will 
damage the fan.  
A.8 Control 
Specifications 
A.8.1 Current 
Loop 
Feature Details 
Controller type 
Vector, digital 
Compensation for bus voltage 
variations 
“On-the-fly” gain scheduling 
Motor types 
 AC brushless (sinusoidal) 
 DC brushless (trapezoidal) 
 DC brush 
 Linear motors 
 Moving coils 
Current control 
 Fully digital 
 Sinusoidal with vector control 
 Programmable PI control filter based on a 
pair of PI controls of AC current signals and 
constant power at high speed 
Current loop bandwidth 
 < 2.5 kHz 
Current sampling time  
Programmable 70 - 100 
µsec  
Current sampling rate 
Up to 16 kHz; default 11 kHz 
 
Tuba Installation Guide 
Technical Specifications 
MAN-TUBIG (Ver. 1.3)
 
 
A-7