Cyclades Marine Instruments 2.3.0 Manuale Utente

Pagina di 160
4: Configuring the Web Interface
AlterPath Console Server User Manual
105
By selecting the appropriate radio button, you can configure ACS to:
Buffer Syslog at all times.
Buffer only when nobody is connected to the port.
To configure data buffering to send alarm notifications, use the 
Notifications form (Expert Mode: Administration > Notifications).
3. When done, select the Apply Changes button located at the bottom of the 
ACS configuration window. 
Ports > Physical Ports > Multi-User
The Multi User form enables you to open more than one common and sniff 
session (multiple sessions) from the same port. 
If configured as No (i.e., do not allow multiple sessions), only two users can 
connect to the same port simultaneously. If configured as Yes, more than two 
simultaneous users can connect to the same serial port. 
A Sniffer menu is presented to the user and they can choose to:
Open a sniff session
Open a read and/or write session
Cancel a connection
Send a message to other users connected to the same serial port. 
If it is configured as RW, only read and/or write sessions will be opened, and 
the sniffer menu won’t be presented. 
If configured as “sniff_session” only, a sniff session will be opened, and the 
sniffer menu won’t be presented. Default value: no. 
Syslog Buffer Size
Maximum size of the buffer.
Field Name
Definition