model are provided on the product data sheets available through FMC or your 
authorized FMC reseller.  FMC does not recommend using the pump in static lift 
conditions without prior factory approval. 
4.5 
Discharge Piping Recommendations 
 
1.  Route the discharge 
piping in as short 
and direct a route as 
possible.  Use the 
same pipe size as 
the outlet of the 
pump.  In 
installations where 
the discharge piping 
is in excess of 50 
feet (15 meters) it is 
suggested to use the 
next larger size pipe 
to minimize friction 
losses downstream 
of the pump. 
 
 
 
 
 
 
          14.5 psi = 1 Bar 
Table 1:  Pipe Pressure Chart 
 
CAUTION: Always use pipe or hose that is designed for your particular pressure 
requirements.  Inadequate pressure ratings can allow hose or pipe to fail, 
resulting in equipment damage and possibly personal injury.  Normal hose 
pressure ratings are clearly marked on the outer surface of the hose.  
Working pressure ratings for steel pipe can be obtained from the 
manufacturer or from the chart shown in Table 1. 
2.  Always use a pressure gage in the pump discharge line.  A properly 
functioning gage mounted at the pump (and before any valves) is required to 
accurately determine the operating pressure of a pump and to conduct 
troubleshooting. 
3.  Insure that all piping is supported independently of the pump to reduce vibrations 
and strain on the pump.  Pulsation dampeners on the discharge are 
recommended to reduce pressure pulsation and resulting vibration.  The use of 
elbows, nipples, unions, or other fittings should be kept to an absolute minimum.  
Avoid short radius 90
°
 elbows; use two long radius 45
°
 elbows instead.  To help 
isolate mechanical and hydraulic vibrations, FMC recommends the use of flexible 
pipe couplings or hose connections between the pump and any rigid piping or the 
use of pulsation dampeners. 
4.  A properly adjusted pressure relief valve or rupture disc must be installed directly 
downstream of the pump to prevent damage or injuries resulting from over 
pressure or deadhead conditions.  The relief valve discharge line must be as large 
as the pipe outlet of the relief valve.  Never install valves in the relief valve 
Allowable Working Pressure For Steel Pipe (PSI @ 100F)
Pipe
Pipe Schedule Number
Size (inches)
40
80
120
160
XX
1/2
2,300
4,100
7,300
12,300
3/4
2,000
3,500
8,500
10,000
1
2,100
3,500
5,700
9,500
1 1/4
1,800
3,000
4,400
7,900
1 1/2
1,700
2,800
4,500
7,200
2
1,500
2,500
4,600
6,300
2 1/2
1,900
2,800
4,200
6,900
3
1,600
2,600
4,100
6,100
3 1/2
1,500
2,400
5,600
4
1,400
2,300
3,350
4,000
5,300
5
1,300
2,090
2,950
3,850
4,780
6
1,210
2,070
2,850
3,760
4,660
8
1,100
1,870
2,840
3,700
3,560