A.  Cooling  Operation 
The  vapor  refrigerants  that  compressed  to  high  temperature  &  high  pressure  conditions  in  the 
compressor,  turn  into  liquid  refrigerant  of  high  temperature  and  high  pressure  passing  through  the 
condenser,  and  then  turn  into  the  liquid  refrigerants  of  low  temperature  and  low  pressure  conditions  by 
passing  through  the  capillary  tubes.  The  liquid  refrigerant  of  low  temperature  &  low  pressure  absorbs 
the  surrounding  heat  while  evaporating  in  the  evaporator.  Then,  it  is  sucked  in  the  compressor  by 
turning  into  saturated  vapor. 
 
B.  Function  of  Parts 
  Compressor:  Compresses  the  vapor  refrigerant  sucked  from  the  evaporator  and  discharges  it  to 
condenser 
  Condenser:  Changes  the  compressed  vapor  refrigerant  into  the  liquid  refrigerant  by  cooling. 
  Drier:  Removes  moisture  and  dirt  inside  pipes 
  Capillary  tube:  Reduces  the  pressure  of  liquid  refrigerant  and  evaporates  it  in  the  evaporator 
under  constant  pressure. 
  Evaporator:  Absorbs  the  surrounding  heats  while  evaporating  the  liquid  refrigerant,  cools  down 
water  inside  of  cold  water  tank. 
  Cold  water  thermostat:  Senses  the  temperature  of  cold  water  tank  and  controls  the  electric  power 
supply  to  the  compressor  automatically  in  order  to  keep  the  constant  temperature  of  cold  water. 
  Over  Load  Protector  (OLP):  Protects  the  compressor  and  operates  when  rising  up  to  abnormal 
temperature  or  energizing  over  current.   
  PTC  Starter:  Starts  up  the  motor  of  compressor.   
  Drain  cap:  By  opening  this,  you  may  drain  out  remaining  water  in  hot  water  tank  when  cleaning 
or  not  using  cooler  for  a  long  period  of  time. 
 
3.  LOCATION  REQUIREMENTS 
A. This  unit  is  intended  to  be  installed  underneath  a  conventional  kitchen  sink,  in  a  cabinet  not  less 
than  36”"  (914mm)  wide  (inside  dimension).  Chiller  may  be  installed  in  any  location  in  the  cabinet 
base  as  long  as  there  is  a  minimum  of  5”"  (127mm)  between  unit  and  cabinet  walls.  In  order  to 
have  necessary  air  exchange  for  the  unit,  a  free  air  opening  of  at  least  60  square  inches  (387 
cm²)  should  be  provided  in  the  kitchen  counter.  The  opening  should  be  located  as  close  to  the 
unit  as  possible  and  can  be  made  in  the  ‘ toe  space  of  the  counter’  or  ‘ above  the  toe  space’ 
B. Make  sure  installation  ground  is  flat  and  even.  -  Unbalanced  placement  may  cause  excessive 
noise  and  trembling  of  the  cooler. 
C. Coolers  are  for  indoor  use  only.  Keep  away  from  direct  sunlight  and  excessive  moisture. 
D. Avoid  harmful  gas  or  excessive  heat.