10.2.   Firmware Upgrade via FTP 
 
Upgrading the firmware via FTP is the fastest way. But this process is available only when the network is in 
normal state and connected properly.   
The following example shows how a command line FTP client is used to upload new firmware (“CWP-
100.fls”) to the CWP-100 when its IP address is 192.168.0.36. Enter “admin” as the user name and type in 
the password that is set on the VoIP configuration web page. The default password is “0000.” 
 
C:\> ftp 192.168.0.36 
Connected to 192.168.0.36. 
220 Precise/RTCS FTP Ready 
User (192.168.0.36:(none)): admin 
331 Password required for admin 
Password:    
비밀번호
(4
자리숫자
입력
 
230 Logged in   
ftp> bin 
200 Type OK 
ftp> put CWP-100.fls flash 
200 Port command okay 
150 Opening data connection for STOR (192.168.0.14,1161) 
226 File received OK – 1053136 bytes in 10.640 sec 
ftp: 1053136 bytes sent in 10.55Seconds 99.82Kbytes/sec.
 
 
The system will reboot automatically when upgrading the firmware via FTP is completed. 
 
 
CAUTION: Do not interfere until upgrading the firmware is completed. Upgrading procedure 
normally takes few minutes by using FTP. The system will restart automatically when the process 
is completed.   
 
We recommend that you reset the system by factory value after the firmware upgrade. Follow the 
steps as”4. Extra Setting” ”7. Firmware”  ”1. Load Default” to reset the system.