Chauvet Baby Accessories 3P Manuale Utente

Pagina di 35
 
 
 
 
Setup 
 
 
 
 
 
 
 
 
COLORado™ 3P User Manual 
 
12 
3/17/2009 9:54 AM 
cable please use data-grade cables that can carry a high quality signal and are less prone to 
electromagnetic interference.  
D M X  D a t a   C a b l e 
Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. 
Standard microphone cables cannot transmit DMX data reliably over long distances. The cable will 
have the following characteristics: 
 
2-conductor twisted pair plus a shield 
 
Maximum capacitance between conductors 
– 30 pF/ft. 
 
Maximum capacitance between conductor and shield 
– 55 pF/ft. 
 
Maximum resistance of 20
Ω / 1000 ft. 
 
Nominal impedance 100 - 140
Ω 
C a b l e   C o n n e c t o r s 
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.  
CAUTION 
Do not allow contact between the common and the fixture’s chassis ground. 
Grounding the common can cause a ground loop and your fixture to perform 
erratically. Test cables with OHM meter to verify correct polarity and to make 
sure the pins are not grounded or shorted to the shield or each other. 
3 - P i n   t o  5 - P i n  C o n v e r s i o n   C h a r t 
Note! 
If you use a controller with a 5 pin DMX output connector, you will need to use 
a 5 pin to 3 pin adapter. CHAUVET Model No: DMX5M. 
The chart below details a proper cable conversion: 
3
 
P
IN TO 
5
 
P
IN 
C
ONVERSION 
C
HART
 
Conductor 
3 Pin Female (output) 
5 Pin Male (Input) 
Ground/Shield 
Pin 1 
Pin 1 
Data ( - )signal 
Pin 2 
Pin 2 
Data ( + ) signal 
Pin 3 
Pin 3 
Do not use 
 
Do not use 
Do not use 
 
Do not use 
COMMON 
DMX + 
DMX - 
INPUT 
OUTPUT 
1 
3 
2 
1 
3 
2 
1 
3 
2 
Resistance 120 
ohm 1/4w between 
pin 2 (DMX -) and 
pin 3 (DMX +) of 
the last fixture. 
Termination reduces signal errors and 
to avoid signal transmission problems 
and interference, it is always 
advisable to connect a DMX signal 
terminator. 
DMX connector configuration