Alvarion BREEZENET BU-DS.11 Manuale Utente

Pagina di 92
BreezeNET DS.11 Series User Manual 
  
 
3-26 
 
Send Trap Interval (sec): The time interval between two successive traps 
when the number of transmitted broadcasts/multicasts exceeds the 
permitted threshold. 
The range is from 0 to 65535 seconds. 0 is for disabling traps sending. 
The default is 300 seconds. 
Auto-Config Tab 
The Auto-Config tab enables quick configuration of various modes by setting 
predefined values for several parameters upon clicking the applicable button. 
 
Figure 
 
3-16: Auto-Config Tab 
♦  Set PtP Mode: Click to set the following parameters to support optimized 
configuration for Point-to-Point operation: 
 
Minimum Contention Window = 15 
 
RTS Threshold = 2437  
♦  Set PtMP Mode: Click to set the following parameters to support optimized 
configuration for Point-to-Multi-Point operation with 2-5 RBs: 
 
Minimum Contention Window = 63 
 
RTS Threshold = 2437 in BU, 60 in RB