BENDIX SD-08-2417 Manuale Utente

Pagina di 12
11
ASSEMBLY
1.  Lubricate the smaller o-ring and check valve body with  
a heavy-duty lithium grease.
2.  Install this o-ring on the check valve body by sliding the 
o-ring over the set of four tapered guide lands.  The  
o-ring groove holds the o-ring in its correct location.  
3.  At the other end of the check valve body, the spring is 
installed over the set of four straight guide lands.  When 
the spring has been pushed to the correct location, the 
check valve body is designed to hold the end of the 
spring in position: be sure that the spring is not loose 
before continuing with this installation.
4.  Install the assembled check valve body/o-ring/spring 
in the delivery port so that the o-ring rests on its seat 
and the free end of the spring is visible.
5.  Grease the adapter and the remaining larger o-ring and 
install it onto the fitting.  
6.  Position the governor gasket, then insert the governor 
mounting bolts through the governor and tighten (to 
125  in-lbs).    Note:  Do not replace with a standard 
compressor/governor gasket.
7.  Re-attach the air line to the governor.
8.  Before  placing  the  vehicle  back  into  service,  check 
to see that the system pressure now builds to full 
operational pressure.
TESTING THE EVERFLOW
®
 ASSEMBLY AIR DRYERS
Before placing the vehicle in service, perform the following 
tests:
1.  Close all reservoir drain valves.
2.  Build up system pressure to governor cut-out and note 
that one of the AD-IS
®
 EverFlow
®
 Assembly air dryers 
purges with an audible burst of air, followed immediately 
by approximately 30 seconds of air flowing out of the 
purge valve.
3.  Apply and release the service brakes several times to 
reduce system air pressure to governor cut-in.  Note 
that the system once again builds to full pressure and 
is followed by a purge at the other AD-IS EverFlow 
assembly air dryer exhaust.
4.  It is recommended that the total air system be tested for 
leakage to ensure that the AD-IS EverFlow assembly 
air dryers will not cycle excessively.
See Bendix publication BW5057 “Air Brake Handbook.”
TROUBLESHOOTING THE AD-IS
®
  EVERFLOW
® 
ASSEMBLY
Consult the Bendix
®
AD-IS
®
 air dryer service data sheet, 
SD-08-2418, for air dryer maintenance and service 
information.
1.  Excessive dryer purging in the loaded cycle.
•  The purge valves in both dryers must have soft-seat 
turbo cut-off valves. See Figure 7.  Remove the purge 
valve an examine the upper window, replace with soft 
seat purge valve.  
METAL
BLACK 
RUBBER
FIGURE 7- 
IDENTIFICATION OF HARD AND SOFT SEAT PURGE VALVES
HARD SEAT 
SOFT SEAT