Hughes AN6-098P Manuale Utente

Pagina di 94
Chapter 6 • Cabling and connections
 
54
1037312-0001  Revision A
Receive cable
Connect the receive cable to the low noise block converter (LNB) 
as follows:
1. Connect the receive cable (marked with red tape) to the 
receive connector on the LNB.
Figure 43 shows the receive connector location on the J-type 
radio assembly, and Figure 44 shows the connector location 
on the cradle-type radio assembly. In both cases the 
connector is a female F connector.
2. Use a 
7
/
16
-inch torque wrench to tighten the connector to 
20 inch-lb
.
3. Apply dielectric silicone grease to the connection.
4. If necessary, secure the cable with cable ties.     
After the transmit and receive cables are connected to the radio 
and to the IDU, reconnect the power transformer (inside the 
building). Instructions for connecting the IDU are included in the 
IDU installation manual.
Figure 43:  Receive connector – J-type radio
Figure 44:  Receive connector – cradle-type radio