  User Inputs/Outputs
The weight sensor controller has five required user inputs and five optional user outputs.  At least four user 
inputs are required to be connected in order for the ramp to function, whereas none of the user outputs 
must be connected (optional).
Below is a list of the user inputs and outputs, including the designated connector pin number, wire color, 
and description.  Please note the optional user outputs have maximum limitations as specified in the 
“Restrictions” column below.
                     Controller to Vehicle Connections (929.505-3 Amp Connector)
 
Function 
Pin # 
Wire Color 
LED 
Description 
Restrictions
 
Input (Pulse) 
Black 
LD10 
Ramp Enable 
Required
 
Input (Pulse) 
Brown 
LD11 
Ramp Operate 
Required 
 
  Input (Continuous) 
Red 
LD12 
Door Full Open 
Required
 
Input (Pulse) 
Orange 
 
Reset Controller 
Optional
 
Power Supply 
Yellow 
  
+24 V Supply 
10 A Time Delay Fuse
 
Power Ground 
Blue 
  
Ground 
Required
 
Input (Pulse) 
Violet/Yellow 
LD13 
Close All Doors 
Required
 Input 
Violet/Green 
LD14 
Extra 
Optional
                Ramp to Controller Connections (T1730-S14 Thomas & Betts Connector)
 
Function 
Pin # 
Wire Color 
LED 
Description 
Restrictions
 
Input 
Yellow/Red 
LD6 
Pressure Mat Return 
 
 
Power 
Green/Black 
  
Ramp + 24 V 
 
 Power 
Orange/Black  
 Ramp 
Ground 
 
 
Input 
Orange 
LD1 
Ramp full out sensor 
 
 
Input 
Green/Black 
LD2 
Ramp full in sensor 
 
 
Output 
Red/White 
LD29 
Drive Motor + 
 
 
Output 
Yellow 
LD30 
Drive Motor - 
 
 
Input 
Blue 
LD3 
Ramp full up sensor 
 
 
Input 
Yellow 
LD4 
Ramp full down sensor 
 
 
Not Used 
10 
  
  
  
 
 
Not Used 
11 
  
  
  
 
 
Input 
12 
Brown 
LD5 
Ramp manual release sensor 
 
 
Output 
13 
Black/Red 
LD27 
Elevate motor + 
 
 
Output 
14 
Orange/Red 
LD28 
Elevate motor - 
 
                   All Connections on this Connector Optional (929.505-6 Amp Connector)
 
Function 
Pin # 
Wire Color 
LED 
Description 
Restrictions
 
Input 
Green 
  
Relay Power (+24 V) 
10 A Time Delay Fuse
 
Output 
Purple 
  
N.C. Ramp Enabled 
 
 
Output 
Grey 
LD17 
N.O. Ramp Enabled 
Required
 
Output 
White 
  
N.C. Open Door 
 
 
Output 
Black/White 
LD18 
N.O. Open Door 
Required
 
Output 
Black 
  
N.C. Ramp Malfunction 
 
 Output 
7 Red/White 
LD19 
N.O. 
Ramp 
Malfunction 
 
 
Output 
Orange/Red 
  
N.C. Clear Signal 
 
 
Output 
Yellow/White 
LD20 
N.O. Clear Signal 
Required
 
Output 
10 
Blue/White 
  
N.C. Manual Release Unlocked 
 
 
Output 
11 
Green/White 
LD21 
N.O. Manual Release Unlocked 
 
 
Output 
12 
Red/Black 
LD22 
N.O. Ramp alarm 
 
 
Power Ground 
13 
Gray/Pink 
  
Ramp alarm ground 
 
 
Not Used 
14 
  
  
  
 
 
Not Used 
15 
  
  
  
 
 
Not Used 
16 
  
  
  
 
 
Not Used 
17 
  
  
  
 
 
Not Used 
18 
  
  
  
 
Installation Instructions