 Appendix C – System Specifications 
 
C.1 Physical 
 
Width: 
     17.25 
inches 
(43.82 
cm) 
Depth: 
     14.75 
inches 
(37.47 
cm) 
Height:     5.25 
inches 
(13.34 
cm) 
 
Rack size:   
 
 
 
3u high, mounts in EIA-standard 19-inch rack 
 
Weight fully loaded:  
 
 
20 lbs. (9.08 kg) 
 
C.2 Environmental 
 
Operating temperature range: 
 
32°F (0°C) to 125°F (52°C) 
Operating humidity range:   
 
30% to 90% RH, non-condensing 
 
Storage temperature range: 
 
-4°F (-20°C) to 158°F (70°C) 
Storage humidity range:   
 
10% to 90% RH, non-condensing 
 
Heat generated in normal operation: 
170.6 BTU/hr 
 
C.3 Electrical 
 
Both the AC and DC power versions of the ConsoleServer feature redundant power 
supplies. 
 
C.3.1 AC Power 
 
Universal input voltage, auto-switched AC power supplies, switch fused 
 
Input 
voltage:    115/230 
VAC 
AC 
frequency:    50/60 
Hz 
Maximum power consumption: 
 
65 W 
Typical power consumption: 
 
50 W 
 
C.3.2 DC Power 
 
48 volt only, externally fused 
 
Input 
voltage:    -48 
VDC 
Maximum power consumption: 
 
65 W 
Typical power consumption: 
 
50 W