- An  unobstructed  air  way  with  a  depth  of  at  least
1 1/2 in. (38 mm) must be ensured at the back of the
kitchen cabinet.
u
The air-circulation clearances indicated above must be
maintained.
The ventilation from below through the cabinet floor can be
provided with the supplied ventilation grille
 Fig. 7 (3)
 or a
ventilation opening of with a cross-sectional area of at least
31 in
2
 (200 cm
2
). If you are using the supplied ventilation
grille
 Fig. 7 (3)
, proceed as follows:
Fig. 7 
u
In  the  cabinet  floor,  cut  a  ventilation  opening
17 23/32 in. (450 mm) wide and 2 7/32 in. (56 mm) high.
u
Insert the ventilation grille
 Fig. 7 (3)
 into the cutout in the
cabinet floor
 Fig. 7 (1)
.
u
Slide the snap connectors
 Fig. 7 (2)
 into the grille from
behind until the hooks touch the cabinet floor.
u
Fit the cabinet floor (with the ventilation grille snapped
into place) into the cabinet.
4.2 Kitchen cabinet setup
Install the appliance in fixed cabinets only.
Kitchen cabinet setup