Marvel 8SWCEL Istruzione Sull'Installazione

Pagina di 56
USING YOUR SENTRY SYSTEM™ CONTROL
Figure 6 “Single Zone”
Glass and Solid Door Models
Status 
LED
6
ON OFF   Door Ajar       
         Power Failure                       
Hi / Low Temp Upper             
Hi / Low Temp Lower
Figure 7 “Dual Zone”
Glass Door Models
Status
message
Only on glass door models
Initial Power-Up:
Your product will start upon plug-in to power receptacle.  The 
Sentry System LED will be flashing “amber” on single-zone mod-
els, (Figure 6), or displaying “power failure” on dual-zone mod-
els, , (Figure 7), to indicate that a power outage has occurred.  
This is normal as the product was powered-up at the factory for 
quality assurance testing.  Momentarily press and release the 
“ON/OFF” keypad to reset the control alarm status.  The LED 
should indicate steady green (single zone) no alarms (dual zone). 
To turn the unit ON/OFF, press and hold the “ON/OFF” key for a 
minimum of 5 seconds.
Set Display Temperature Units:
Your control is factory set to display temperature in ºFahrenheit 
as indicated by ºF in the upper right corner of the temperature 
display.  If this is the desired temperature units, no action is 
required.  If you prefer to display temperature in ºCelsius, mo-
mentarily press the “ºF/ºC” keypad.  ºC should now be displayed 
in the upper right corner of the temperature display.  You may 
“toggle” between ºF or ºC temperature display at any time by 
momentarily pressing the “ºF/ºC” keypad.
Set Your Desired Storage Compartment Temperature:
Your control is factory set to 55ºF.  This is the ideal long-term 
storage temperature for “both” red and white wines.  The stor-
age compartment temperature can be adjusted throughout the 
full range of red and white wine serving temperatures, (40ºF > 
65ºF).
•  Single-Zone Models, (Figure 6)
To set the storage compartment temperature, momentarily 
press the “Set” keypad.  The display will now change to 
show the current set-point temperature, and “SET” will be 
displayed to indicate that you are in temperature set mode.  
While in SET mode you may press the “Warmer” or “Colder” 
keypads to adjust the set-point to your desired temperature 
in 1º increments. When your desired temperature is dis-
played, you may exit SET mode by momentarily pressing the 
“Set” keypad, or SET mode will time-out after 10 seconds of 
inactivity.
•  Dual-Zone Models, (Figure 7)
The control allows independent temperature control for 
both the upper and lower storage compartments.  On Dual 
Zone models, momentarily pressing  the “Set” keypad will 
select each compartment individually as indicated by SET 
being displayed in the “Upper” or “Lower” compartment 
temperature display.  While SET is displayed, you may press 
the “Warmer” or “Colder” keypads to adjust the storage 
compartment set-point to your desired temperature.  To exit 
SET mode, momentarily press the “Set” keypad until SET is 
no longer displayed in either the Upper or Lower displays, or 
SET mode will time-out after 10 seconds of inactivity. 
Compartment temperatures will be controlled to the tem-
perature displayed when SET mode is exited.
•  All Models:
Important: it is suggested to allow 24 hours after changing 
the storage compartment set-point temperatures before 
making further adjustments.  This will allow the content 
temperatures to stabilize at the new set-point tempera-
ture.  Frequent door openings may prolong this stabilization 
period.
Interior Lighting:
A door activated interior compartment light is provided for your 
convenience.  On glass door models only, this light may also be 
used to enhance the display of your wines through the glass 
door.  To activate the display lighting mode on glass door models, 
momentarily press the “Light” keypad, (Figure 6 & 7).  When ac-
tivated, the interior light will remain on when the door is closed.  
Important: Use the display lighting option only when needed.  
The interior light generates heat which will increase the energy 
consumption of your product.
ON
OFF
Press and hold
Set
Warmer
Colder
F/C
Light
Sentry System™
Power Failure-Flashing Amber
High/Low Temp-Red
Press ON/OFF-Reset
Alarms OFF-Steady Amber