Thermador PH54GS Istruzione Sull'Installazione

Pagina di 50
English 1
Introduction
This manual provides the proper installation instructions for 
two styles of THERMADOR PROFESSIONAL
®
 Series Wall 
Hoods:
27” Pro Wall Hood models (PHxxGS), 27” (686mm) in 
depth, with widths of 36” (914mm), 42” (1067mm), 48” 
(1219mm), and 54” (1372mm). This model series 
features brushed stainless-steel canopy with halogen 
lamps and heat lamps (see Figure 1).
24” Pro Wall Hood models (PHxxHS), 24” (610mm) in 
depth, with widths of 30” (762mm), 36” (914mm), and 
48” (1219mm). This model series features brushed 
stainless-steel canopy with halogen lamps (see 
Figure 1).
All hoods require the choice of a Remote, Inline, or Integral 
Blower. Use only THERMADOR
®
 blowers with 
THERMADOR
®
 ventilation hoods. All blower models are 
sold separately. See Table 1, Blower & Circuit Breaker 
Ratings, for recommended blowers. Contact Customer 
Service for additional options.
 Figure 1:  Pro 24” & 27” Wall Hoods
30”, 36”, 42”, 48”, 54”
(762, 914, 1067, 129, 1372mm)
  
 
18” 
(457
mm)
24”, 27”
(61mm, 686mm) 
12” 
(305
mm
)
B
LOWER
SKU
CFM
V
OLTAGE 
(AC)
B
LOWER 
C
URRENT 
(AMPS)
C
IRCUIT 
B
REAKER
(AMPS)
R
EMOTE 
B
LOWER 
600 CFM
VTR630D
600
120
4.2
15
R
EMOTE 
B
LOWER 
1000 CFM
VTR1030D
1000
120
5.7
15
R
EMOTE 
B
LOWER 
1300 CFM
VTR1330E
1300
120
8.5
20* / 15**
I
NLINE 
B
LOWER 
600 CFM
VTI610D
600
120
4.2
15
I
NLINE 
B
LOWER 
1000 CFM
VTI1010D
1000
120
5.7
15
I
NTEGRAL 
B
LOWER 
600 CFM
VTN630C
600
120
2.7
15
I
NTEGRAL 
B
LOWER 
1000 CFM 
VTN1030C
1000
120
5.4
15
Table 1: Blower & Circuit Breaker Ratings
*  20 Amp circuit breaker required when using the VTR1330E Remote Blower with a 27” Pro Wall Hood.
** 15 Amp circuit breaker required when using the VTR1330E Remote Blower with a 24” Pro Wall Hood.
When connected to a GFCI-protected supply, the Pro Hoods are suitable for use in damp locations that are protected from 
outside weather conditions and not subject to saturation with water and other liquids, but can be subject to moderate 
degrees of moisture. Refer to local codes, NEC/CEC, and or the Authority Having Jurisdiction (AHJ) for additional 
information.