Zephyr CTPE54BSX Manuale Proprietario
![Zephyr](https://files.manualsbrain.com/attachments/565fe8a486ba1d536066ed7aaca7337168601921/common/fit/150/50/fffe26e9186ae104414a60fd6a1808f0f17d5128b734ee4e44d87f794b4d/brand_logo.png)
9
Installation –
Blower Preparation
INTERNAL BLOWER PREPARATION
1. Remove internal blower fl ange from motor
housing by (6) screws.
2. Secure internal blower to internal blower fl ange
by (4) M4*16 screws from internal blower
hardware.
hardware.
3. Secure AC power wiring box to internal blower
fl ange by (2) M4*8 screws.
4. Secure ground wire to underside of internal
blower fl ange by (1) 3/16*3/8 screw and (1)
washer.
washer.
5. Connect 9 pin molex connector from capacitor
cable to 9 pin molex connector from internal
blower.
blower.
6. Re-install internal blower fl ange to motor
housing by (6) screws previously removed from
step 1.
step 1.