Frigidaire FFTA1233Q2 Istruzione Sull'Installazione

Pagina di 14
2
Installation Instructions
How to Install
1.  Identify the wall-sleeve brand for your installation, from the chart below.
Brand
Wall Sleeve Dimensions
Width
Height
Depth
General Electric/Hotpoint
26
15
5
8
15
7
8
Sears/Kenmore
25
3
4
16
7
8
18
5
8
Carrier (51S Series)
18
5
8
16
7
8
25
3
4
Friedrich*
16
3
4
16
3
4
27
Emerson/Fedders*
15
15
3
4
26
3
4
Whirlpool
25
7
8
16
1
2
17
1
8
or 23
Fedders/Emerson*
27
16
3
4
16
3
4
19
3
4
or
White-Westinghouse
25
1
2
15
1
4
16, 17
or 22
1
2
Frigidaire
25
1
2
15
1
4
16, 17
or 22
1
2
Carrier (52F Series)
25
1
2
15
1
4
16, 17
or 22
1
2
CAUTION:
When installation is complete, replacement unit MUST have a rearward slope as shown in Fig.1.
2.  Remove old Air Conditioner from wall sleeve and prepare wall sleeve as follows:
Clean interior (do not disturb seals).
Wall sleeve must be securely fastened in wall before installing Air Conditioner. Drive more nails or screws through
sleeve, into wall, if needed. 
Retouch wall sleeve painted surface if needed.
 Wall
sleeve
 REAR
 1/4" to 5/16"
 FRONT
 LEVEL
UNIT
 Fig.1
3.  If not existing, drill a 3/16" clearance hole for grounding screw through left side of wall sleeve, in a clear area about
     3 inches maximum back from front edge of sleeve, using grounding screw and toothed washer. Pull loose end 
     of ground wire out front of sleeve, and temporarily bend it down and around lower edge of sleeve (Fig.2). This 
     ground wire will later be attached to frame of air conditioner once it is installed.
Wall sleeve to unit
sleeve grounding
 Max.
 Hole
 Fig.2
IMPORTANT
All wall sleeves used to mount the new Air Conditioner must be in sound structural condition and have a rear 
grille that securely attaches to sleeve, or rear flange that serves as a stop for the Air Conditioner.
For new installations, a Frigidaire Sleeve Kit (EA108T) is recommended.
For larger sleeves, an adaptor trim kit (EA120T) is available.