Viking RVEWD330WH Guida All'Installazione

Pagina di 6
7
6
Cutout Dimensions
A
C
B
RVEWD
Cutout width (A)
28-1/4” (71.8 cm)
Cutout depth (B) 23-1/2” (59.7 cm)
Cutout height (C)
9-1/4” (23.5 cm)
Indoor
Flush Mount Option:
Note: To install the warming drawer in a flush mount application, a flush mount
accessory kit is required and sold separately.
RVEWD
Cutout width (A)
29-5/8” (75.3 cm)
Cutout depth (B) 25-1/8” (63.8 cm)
Cutout height (C) 10-1/8” (25.7 cm)
Electrical Requirements
WARNING
ELECTRICAL SHOCK
HAZARD
To avoid the risk of electrical
shock, personal injury or death;
verify electrical power is turned off at the
breaker box until the range is installed
and ready to operate, installation by an
authorized installer only.
RVEWD
Max. amp 
usage
450 watts
3.8 amps
Electrical Requirements
Check your national and local codes
regarding this unit. Hard wire direct with
seperate 120V/15 amp minimum 2-wire
wtih ground circuit. Maximum amp usage.
Electrical Connection
Note: Use copper conductors ONLY!
Grounding Instructions
This appliance must be connected to a
grounded metal, permanent wiring system,
or an equipment-grounding conductor
must be run with the circuit conductors and
connected to the equipment-grounding
terminal or lead on the appliance.
With the appliance positioned in front of
the cabinet opening, connect wire leads
extending from the power supply to the
terminal block of the unit. Make sure the
colored wires of the terminal block are
connected to the corresponding colored
wires extending from the power supply.