Maytag MGT8655XB-BL Guida All'Installazione

Pagina di 40
8
Make Gas Connection
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the 
smaller thread ends of the flexible connector adapters (see B 
and G in the following illustration). 
2. Attach one adapter to the gas pressure regulator and the 
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a 
¹⁵⁄₁₆" combination wrench and an adjustable wrench to 
attach the flexible connector to the adapters. Check that 
connector is not kinked.   
4. Gas supply pipe must be located within the shaded area as 
shown in the “Cabinet Dimensions” illustration in “Location 
Requirements” section.
Complete connection
1. Open the manual shutoff valve in the gas supply line. The 
valve is open when the handle is parallel to the gas pipe.
2. Test all connections by brushing on an approved 
noncorrosive leak-detection solution. If bubbles appear, a 
leak is indicated. Correct any leak found.
3. Remove cooktop burner caps and grates from parts 
package. Align recess in burner caps with pins in burner 
base. Burner caps should be level when properly positioned. 
If burner caps are not properly positioned, surface burners 
will not light. Place burner grates over burners and caps.
4. Plug into a grounded 3 prong outlet.
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have ½" male 
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F. ½" or ¾" gas pipe
G. Use pipe-joint compound.
H. Adapter
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
C
D
E
F
G
H
A. Gas pressure regulator
B. Adapter
C. Flexible connector
D. Manual shutoff valve
A. Closed valve
B. Open valve
Adaptor
A
B
C
D
A
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.