To determine if there is an active alarm condition:
1
Press Escape until 
CAMPUS RS I/F: REX2 
is displayed.
2
Press Next three times. 
ALARM CONFIG & STATUS
 is displayed.
3
Press Enter. The LCD displays these Alarm types:
Current Alarms HDSL
HDSL Link Alarms
 Config and Status
Local I/F Alarms Config and Status
RMT I/F Alarms Config and Status
If a specific indicator does not display, there is no alarm in that area of 
the system.
The following sections describe how to view specific alarm information for 
the HDSL, local, and remote ports, and how to configure thresholds.
HDSL Alarms
This section describes how to view and configure alarms on the HDSL line.
Viewing Current Alarms
If the 
CURRENT ALARMS
 display indicates an HDSL alarm, you can 
determine the alarm type:
1
From the 
CURRENT ALARMS
 display, press Next
HDSL LINK 
ALARMS CONFIG & STATUS
 is displayed.
2
Press Enter. The current status of three alarms is displayed:
LINK
 shows whether the HDSL link is on or off
ES
 shows whether the errored seconds threshold has been exceeded 
on the local unit, remote unit, or both
MARGIN
 shows whether the margin threshold has been exceeded on 
the local unit, remote unit, or both