Viewing 24-Hour HDSL Alarm History
You can view the number of HDSL alarm conditions that have occurred over 
the past 24 hours. The LCD displays 24-hour information for the following 
alarms:
local errored seconds (
LOCAL ES
)
remote errored seconds (
REMOTE ES
)
local unavailable seconds (
LOCAL UAS
)
remote unavailable seconds (
REMOTE UAS
)
You may also view the time when the counter was last cleared and clear the 
counter. 
To view the HDSL alarm history:
1
Press Escape until 
CAMPUS RS I/F: REX2 
is displayed.
2
Press Next
HDSL LINK CONFIG & STATUS
 is displayed.
3
Press Enter, then press Next until 
PERFORMANCE STATUS
 is 
displayed.
4
Press Enter, then press Next to scroll through the alarm history is 
displayed.
5
To reset the counter, press Next until 
Press ENTER to clear 
error cnts
 is displayed, then press Enter.
Local Alarms
Loss of Signal (LOS) alarms can occur on the local unit. This section 
describes how to view and configure this alarm.
Viewing Current Alarms
If the 
CURRENT ALARMS
 display indicates a local alarm, you can determine 
the alarm type:
1
From the 
CURRENT ALARMS
 display, press Next twice. 
LOCAL I/F 
ALARMS CONFIG & STATUS
 is displayed.
2
Press Enter. The current status of the local alarm is displayed.