11. POSITIONING DEBUGGING 
 
DISPLAY/SETTING DATA
 
 
Item Description 
JOG speed limit 
Shows the JOG operation limit value set to the extended parameters 2 (refer to Section 
8.1.4). 
JOG speed 
Set the speed for JOG operation. 
You cannot set any value beyond the JOG speed limit. 
Fwd JOG ( 
 ) 
Rev JOG ( 
 ) 
Choose the arrow ( 
 ) of the axis for JOG operation, move the mouse pointer to the 
arrow, and press the mouse's left button or the space key to start JOG operation. 
Hold down the mouse's left button or the space key to continue JOG operation. 
The arrow is red during operation. 
"#1 stop" button 
"#2 stop" button 
"#3 stop" button 
Click the corresponding button to stop the axis on which the positioning start test is being 
made. 
Reset the error after a stop since the axis results in an error occurrence status. 
These buttons cannot be clicked during JOG operation. 
"All stop" button 
Click this button to stop all operating axes. 
Reset the error after a stop since the axis results in an error occurrence status. 
"Error reset" button 
 / 
 / 
 ) 
Click any button to reset the error of the corresponding axis. 
"M code Off" button 
 / 
 / 
 ) 