Mitsubishi Electronics A1SD75M1/M2/M3 Manuale Utente

Pagina di 212
 
 
 
11 - 41                                                                                                                                                       11 - 41 
MELSOFT
11. POSITIONING DEBUGGING 
 
11.2.7 MPG operation test 
PURPOSE
 
 
MPG operation allows the following tests to be made during debugging of 
positioning. 
• Checking of the ON/OFF of the external signals such as upper/lower limit, zero 
phase and DOG signals 
• Measurement of backlash compensation by forward or reverse operation 
• Measurement of accurate addresses and travel distances 
 
BASIC OPERATION
 
 
1. Perform the basic operation in Section 11.1.2 to start operation monitor. 
2. Click the [Online] 
→ [Test] → [Test start] menu ( 
 ). 
3. Click the "OK" button in the test mode start confirmation dialog box. 
4. Click the "Ope. Test" button on the operation monitor main screen. 
5. Click the <<MPG>> tab in the Test data set dialog box. 
6. Enable MPG operation. 
7. Perform MPG operation. 
8. To end the MPG operation test, click the [Online] 
→ [Test] → [Test start] menu ( 
 ). 
9. Clicking the "OK" button in the test mode end confirmation dialog box returns to 
the operation monitor status. 
 
DISPLAY/SETTING SCREEN