Vermont Casting ODGSR42A Manuale Utente

Pagina di 20
10
ODGSR Series Outdoor Gas Fireplace
20007114
LG320
ODUVSR42
log flames
11/24/03  djt
LG320
Fig. 15  ODGSR42A flame appearance.
Fig. 16  Proper pilot flame height.
FP581
3/8"-1/2"
FP581
NVB-PILOTS
12/4/97
ELECTRONIC
IGNITION
NOVA SIT Pilot
LG319
ODUVSR36
log flames
11/24/03  djt
Red Glow
LG319
Fig. 14  ODGSR36A flame appearance.
Flame Adjustment
For units equipped with Hi/Lo valves, flame adjustment 
is accomplished by rotating the Hi/Lo adjustment knob 
located near the center of the gas control.
LO
HI
Turn 
counterclockwise
to increase 
flame height
Turn clockwise
to lower
flame height
FP390
FLAME ADJUSTMENT KNOB
11/21/96
Fig. 13  Flame adjustment knob for SIT820 valve.
Flame Characteristics
It is important to periodically perform a visual check of 
the pilot and the burner flames. Compare them to the il-
lustrations below (Figs. 14, 15, 16).  If any of the flames 
appear abnormal call a service person.