6
Figure 6 - Lineal Gain
LINEAL GAIN
PART NO.
DESCRIPTION
GAIN
36"
Fireplace
40"
12-8DM
12-8HT
Pipe Section
10 
/
8
"
18-8DM
18-8HT
Pipe Section
16 
/
8
"
24-8DM
24-8HT
Pipe Section
23 
/
8
"
36-8DM
36-8HT
Pipe Section
34 
/
8
"
48-8DM
48-8HT
Pipe Section
46 
/
8
"
RT-8DM
Round Termination
7
/
8
"*
RTL-8DM Round Termination
3
/
4
"*
RTT-8DM
Round Termination 
with Slip Section
7
/
8
" to 
23 
1
/
8
"*
RTTL-8DM
Round Termination 
with Slip Section
1
/
2
" to 
21 
1
/
2
"*
ET-8DM
Square Chase-Top
12"*
ETO-8DM
Square Chase-Top 
with Mesh
12"*
ETL-8DM
Square Chase-Top 
with Slip Section
7" to 1"*
ETLO-8DM
Square Chase-Top 
with Mesh & Slip 
Section
12" to  
1
/
2
"*
* The lineal gain for the terminations is mea-
sured to the flue gas outlet height.
Hemmed 
End
12 
3
/
8
Stainless 
Inner Pipe
12" Galvanized 
Outer Pipe
ASSEMBLY AND INSTALLATION OF 
DOUBLE WALL CHIMNEY SYSTEM
Each double wall chimney section consists of a 
galvanized outer pipe, a stainless steel inner flue 
pipe and a wire spacer. The pipe sections must be as-
sembled independently as the chimney is installed. 
When connecting chimney directly to the fireplace, 
the inner flue pipe section must be installed first 
with the lanced side up. The outer pipe section can 
then be installed over the flue pipe section with the 
hemmed end up. Press down on each pipe section 
until the lances securely engage the hem on the fire-
place starter. The wire will assure the proper spacing 
between the inner and outer pipe sections.
Venting inStallatiOn
OPTIONAL OUTSIDE AIR KIT 
(MODEL AK4/AK4F)
The installation of an outside air kit should be per-
formed during the rough framing of the fireplace 
due to the nature of it's location. Outside combus-
tion air is accessed through a vented crawl space 
(AK4F) or through a sidewall (AK4).
  CAUTION:  Combustion  air 
inlet  ducts  shall  not  terminate 
in attic space.
Figure 5 - Outside Air Kit
Secure to Collars with Metal Tape, 
Screws or Straps (Min. of 1/4" x 20" 
in size)
Air Inlet 
Location 
Must Allow 
For Bushes 
or Snow
Vent Hood 
Required for 
Wall Installation
Air Inlet 
Eyebrow
Vented Crawl Space
(Check Local Codes 
Before Installing in a 
Vented Crawl Space)
CHIMNEY PIPE
The DESA chimney system consists of 12", 18", 
24", 36" and 48" snap-lock, double-wall pipe 
segments,  planned  for  maximum  adaptability 
to individual site requirements. Actual lengths 
gained after fitting overlaps must be taken into 
consideration (lineal gain) and are given in the 
lineal gain chart (see Figure 6). Lineal gain is the 
actual measurable length of a part after two or more 
parts are connected. For Canada, use chimney parts 
designated "HT".
 WARNING: The opening in the 
collar  around  the  chimney  at  the 
top  of  the  fireplace  must  not  be 
obstructed. Never use blown insula-
tion to fill the chimney enclosure.