Desa VDCFTPB Manuale Utente

Pagina di 44
www.desatech.com
116526-01B
27
iNspECTiNG BURNERs
Check pilot flame pattern and burner flame pat-
terns often.
PILOT FLAMe PATTeRN
Figure 45 shows a correct pilot flame pattern. 
Figure 46 shows an incorrect pilot flame pattern. 
The incorrect pilot flame is not touching the ther-
mocouple. This will cause the thermocouple to 
cool. When the thermocouple cools, the fireplace 
will shut down.
If pilot flame pattern is incorrect, as shown in 
Figure 46
•  turn fireplace off (see To Turn Off Gas to Appli-
ance, page 22 for Thermostat-Controlled Mod-
els or page 24 for Remote-Ready Models)
•  see Troubleshooting, page 29
Note:
 The pilot flame on natural gas units will 
have a slight curve, but flame should be blue and 
have no yellow or orange color.
Figure 45 - Correct Pilot Flame Pattern 
(Propane/LP Remote-Ready Shown)
Pilot Burner
Thermocouple
Figure 46 - Incorrect Pilot Flame Pattern 
(Propane/LP Remote-Ready Shown)
Pilot Burner
Thermocouple
BURNeR FLAMe PATTeRN
Figure 47 shows a correct burner flame pattern. 
Figure 48 shows an incorrect burner flame pattern. 
The incorrect burner flame pattern shows sporadic, 
irregular flame tipping. The flame should not be 
dark or have an orange/reddish tinge.
Note:
 When using the fireplace the first time, the 
flame will be orange for approximately one hour 
until the log cures. 
If burner flame pattern is incorrect, as shown in 
Figure 48
•  turn fireplace off (see To Turn Off Gas to Appli-
ance, page 22 for Thermostat-Controlled Mod-
els or page 24 for Remote-Ready Models)
•  see Troubleshooting, page 29
Figure 47 - Correct Burner Flame Pattern
Figure 48 - Incorrect Burner Flame 
Pattern 
ClEaNiNG aND 
maiNTENaNCE
 WARNING: Turn off fireplace 
and let cool before cleaning.
  CAUTION:  You  must  keep 
control  areas,  burner  and  cir-
culating  air  passageways  of 
fireplace  clean.  Inspect  these 
areas  of  fireplace  before  each 
use.  Have  fireplace  inspected 
yearly  by  a  qualified  service 
person.  Fireplace  may  need 
more frequent cleaning due to 
excessive  lint  from  carpeting, 
pet hair, bedding material, etc.
  WARNING:  Failure  to  keep 
the  primary  air  opening(s)  of 
the burner(s) clean may result in 
sooting and property damage.
BURNER INjECTOR HOLDER AND 
PILOT AIR INLeT HOLe
The  primary  air  inlet  holes  allow  the  proper 
amount of air to mix with the gas. This provides 
a clean burning flame. Keep these holes clear of 
dust, dirt, lint and pet hair. Clean these air inlet 
holes prior to each heating season. Blocked air 
holes will create soot. We recommend that you 
clean the unit every three months during operation 
and have fireplace inspected yearly by a qualified 
service person.