module. Each of the three possible host streams will report its own unique sequence number. 
Note that if a previously stopped data stream is restarted, the returned sequence numbers will 
resume with the next number at the point of the stream’s termination. The sequence numbers 
will restart at one (1) only if the streams are reconfigured (with ‘c 00’ sub-commands) A 
bounded stream will terminate once this sequence number equals the requested number of 
scans for the stream. 
For periodic hardware-triggered streams, that are never suspended and resumed after being 
initially enabled, the sequence number may also serve as a “relative” time stamp if the period (in 
milliseconds) of the hardware trigger is known. 
If a special sub-command (‘c 05’) is used to select the Data Group content of a stream, other 
binary status data may immediately follow the binary stream header and precede the default 
Temperature/Resistance EU Data (if selected).  Other special acquired data groups (per 
selected channel) may follow or replace the Temperature/Resistance EU Data.  Each datum 
group in each scan will be ordered from highest channel number requested to lowest channel 
number requested.  Each datum (dddd) will be output per the format code specified when the 
stream was configured (by sub-command “c 00 or combination of “c 00” and “c 05”). 
Example: 
Start all the streams configured in the previous example: 
"c 01 0
Read response: 
"A
Soon after the response is received, the requested data stream scans will begin arriving in the 
host at a quantity, content, and rate determined by each stream’s own particular current 
configuration (per both the "00" and "05" sub-commands).
 
Note
 
NUSS uses this sub-command to start data acquisition on its Run 
forms. If the default Run State 0 stream configuration is used, all 
forms of data from a module are acquired for all channels, at 
various rates (see NUSS note at end of ’c 00’ sub-command) and 
made available to a Run form’s Display and Record functions. This 
default Run State 0 collection of streams will likely contain too 
much data for "efficient" recording of just E.U. data. For such 
requirements, NUSS has a Run State Editor for creating other 
"custom" Run States (1-9) that can be assigned to a Run form. 
These can generate more efficient stream configurations for high-
speed data recording, including hardware-triggered synchronized 
scans.