RAD Data comm Modular Access Device with Integrated Router Manuale Utente

Pagina di 224
Chapter 5  Setup Menu 
FCD-IPM Installation and Operation Manual 
5-92 
WAN Economy Menu
 
 
Table 5-32.  Connection On Demand Parameters (Cont.) 
Parameters Possible 
Values 
Description 
Minimum Time 
Between 2 
Connections 
 
Determines how much time there must be between a line being 
terminated and then reactivated. This option is only used when 
upon power up is chosen in start connection. All other options are 
determined by the frame traffic 
Minimum Time 
Between 2 
Disconnections 
 
Determines the minimum time between two disconnections. Using 
this option allows you to determine a minimum time-up. This 
option overrides other terminate connection options 
Connect Manually 
 
Activates a line immediately. This option overrides any other 
connection option, including minimum time between 2 connections 
Disconnect Manually 
 
Terminates a line immediately. This option overrides any other 
terminate option, including minimum time between 2 
disconnections 
 
The following examples demonstrate how COD can be used. 
Example 1: 
A company needs their FCD-IPM to be connected to the Internet 24 hours a day. 
Therefore the following must be defined: 
Start connection is upon power up 
Terminate Connection is never (see 
ISDN
INTERNET
The connection is
permanent
Connection is never
terminated
FCD-IPM
 
Figure 5-92.  Permanent Connection