Hoover cleaner Manuale Utente

Pagina di 13
10
3-5
3-6
3-7
Removing filter
Lift out filter (F) and hand wash it in cold
water with mild detergent.
Let filter air dry and reposition it on 
the front of the cleaner. Reposition retain-
er and filter bag door.
Should you want to replace this filter, ask
for HOOVER 
part No. 38765024.
Installing bulb and reposition-
ing hood
Pull old bulb straight out of socket.
Push new bulb straight into socket until
locked in place.
Excessive force is not required.
Reposition hood and push firmly to snap
it into place on the sides and at the
front.
Note:
It is not necessary to turn the
cleaner over and use a screwdriver to
remove the hood once you are familiar
with the 2 places on the hood (indicated
by arrows in Fig. 3-6) that unlatch it.
Simply pull the sides of the hood out-
ward at those areas and lift off the hood. 
Belt replacement
The belt on your HOOVER cleaner 
causes the agitator to rotate and is
important for the effective operation of
the cleaner.  The belt is located under
the bottom plate of the cleaner and
should be checked from time to time 
to be sure it is in good condition.
When to replace
To check belt, remove bottom plate as
shown in “How to replace.”  Replace
belt if it is stretched, cut or broken.
What to buy
To assure effective operation, use only
genuine HOOVER belts with your 
cleaner.  When purchasing a new belt,
ask for Hoover 
part No. 40201190.
Positioning belt over brush
roll
Insert brush roll through belt and place
belt in belt guide (I) on brush roll.
Installing brush roll
Grasp brush roll firmly and fit it into posi-
tion by first sliding belt side into the rec-
tangular slot (J) on side of cleaner.
Pull other side of brush roll (K) into place.
Turn brush roll making sure belt is not
pinched between brush roll and cleaner
base. 
How to replace
Removing bottom plate
Disconnect cleaner from electrical 
outlet.
Place handle in low position and turn
cleaner over.
Remove the 2 screws as shown with a
Phillips screw driver.  
Lift  bottom plate at (G) and rotate it off
the cleaner.
Removing used belt
Remove agitator brush roll and 
used belt. 
Discard used belt.
Positioning belt over pulley
With lettering on outside of belt, pinch
belt into a loop and twist slightly to
slide new belt over motor pulley (H).
F
Headlight
What to buy
This cleaner uses a 12 volt, wedge base
type 912 bulb, Hoover 
part No. 27313-
101.
How to replace
Disconnect cleaner from electrical
outlet.
Removing hood
Place handle in low position and turn
cleaner over.
Hood snaps off by inserting the end of
a flat screwdriver into one of the areas
(labeled with an arrow) on either side  of
the cleaner as shown. Push screwdriver
outward to release hood.  Repeat on the
other side and remove hood.
G
3-9
3-10
3-11
H
I
3-12
J
K
3-8