GSI Outdoors 2TFC Manuale Utente

Pagina di 57
2000 Autoflow
40
ELECTRICAL POWER SUPPLY
Fill System Control Box Electrical Load Information
      The following charts provide information for
the electrician wiring the grain dryer, and are a
reference guide for parts.  It is recommended
that you contact your local power company and
have a representative survey the installation to
see that your wiring is compatible with their
system and that adequate power is supplied to
your unit.  Remember that the only thing
connected to the recommended service amps
should be your grain dryer.  Standard electrical
safety should be used.  (Refer to the National
Electrical Code Standard handbook by the
National Fire Protection Association.)  A
qualified electrician should make all electrical
wiring installations.
Fill System 
HP
Voltage
Full Load 
Amps
Motor 
Starter 
Relay 
Heater 
Strips
220v1ph
13
30
C137B
3 HP
220v3ph
7
30
C104B
380v50hz
4
30
C630A
460v3ph
4
30
C630A
575v3ph
3
30
C630A
220v1ph
21
30
C228B
5 HP
220v3ph
12
30
C163B
380v50hz
7
30
C955A
460v3ph
6
30
C778A
575v3ph
5
30
C630A
220v1ph
32
40
C303B
7.5 HP
220v3ph
18
30
C228B
380v50hz
11
30
C151B
460v3ph
9
30
C125B
575v3ph
7
30
C955B
220v1ph
42
60
C366B
10 HP
220v3ph
25
30
C303B
380v50hz
14
30
C180B
460v3ph
12
30
C163B
575v3ph
9
30
C137B
220v1ph
64
75
F658B
15 HP
220v3ph
37
40
C400B
380v50hz
21
30
C273B
460v3ph
18
30
C214B
575v3ph
14
30
C180B
220v3ph
49
60
C500B
20 HP
380v50hz
28
40
C330B
460v3ph
23
30
C303B
575v3ph
19
30
C228B
220v3ph
61
75
F719B
25 HP
380v50hz
35
40
C400B
460v3ph
29
40
C330B
575v3ph
23
30
C273B
220v3ph
73
75
F772B
30 HP
380v50hz
43
60
C440B
460v3ph
35
40
C400B
575v3ph
28
40
C330B
Fill System 
HP
Voltage
Full Load 
Amps
Motor 
Starter 
Relay 
Heater 
Strips