Adtran 612 Manuale Utente

Pagina di 264
Total Access 600 Series System Manual
Section 4  User Interface Guide
61200624L1-1B
© 2004 ADTRAN, Inc.
83
I
NTERFACES
 (FXS) > C
ONFIG
 > P
ORT
Indicates the port of the FXS module.
I
NTERFACES
 (FXS) > C
ONFIG
 > M
ODE
Choices are given below. Default is 
L
OOP
 S
TART
.
I
NTERFACES
 (FXS) > C
ONFIG
 > T
X
 (
d
B)
Sets the TX direction level points. This signal will change the volume of the voice. TX (dB) is the signal 
that is transmitted out the T1, with 0 dB being the strongest. If the volume is too loud across the T1, this 
number should be increased. A higher number indicates more attenuation which equals lower volume. The 
value entered must be less than 10 dB. Default is
 6.0 dB
.
I
NTERFACES
 (FXS) > C
ONFIG
 > R
X
 (
d
B)
Sets the RX direction level points. This signal will change the volume of the voice. A higher number 
indicates more attenuation which equals lower volume. The value entered must be less than 10 dB. Default 
is 
3.0 dB
. The maximum signal is 
0.0 dB
.
This mode must match the network configuration and/or how each port is being used. Each 
port on the FXS Module is independent and should be set accordingly.
L
OOP
 S
TART
Sets the port to use FXS loop start signaling on the T-span and loop start 
supervision on the analog 2-wire interface.
G
ROUND
 S
TART
Sets the port to use FXS ground start signaling on the T-span and ground 
start supervision on the analog 2-wire interface.
TR08 S
INGLE
Sets the port to use Single Party Channel Unit signaling on the T-span 
(as defined by TR-TSY-000008) and loop start supervision on the 
analog 2-wire interface.Only available when using a T1 network 
interface.
TR08 UVG
Sets the port to use Universal Voice Grade signaling on the T-span (as 
defined by TR-TSY-000008) and either loop start or ground start 
supervision on the analog 2-wire interface. Only available when using a 
T1 network interface.
DPO
Sets the port to use Dial Pulse signaling to originate dialed numbers. 
Only available when using a T1 network interface.
T
ANDEM
 (E&M)
Sets the port to use E&M signaling on the T-span and either loop start or 
ground start supervision on the analog 2-wire interface. See the 
T
ANDEM
 
submenus for more information. Only available when using a T1 
network interface.