Section 4  User Interface Guide
Total Access 600 Series System Manual
 84
© 2004 ADTRAN, Inc.
61200624L1-1B
I
NTERFACES
 (FXS) > C
ONFIG
 > S
VC
 M
ODE
Indicates whether the module is 
I
N
 S
ERVICE
 
or 
O
UT
 
OF
 S
VC
. This does not indicate whether the port has 
been mapped. For proper operation, the port must be mapped using the 
DS0 M
APS
 
menu. Default is 
I
N
 
S
ERVICE
.
I
NTERFACES
 (FXS) > C
ONFIG
 > L
INE
 Z
Sets the line impedance. Choices are 
600 
OHMS
, 900 
OHMS
, 600 
OHMS
 + 2.16
µ
F, 900 
OHMS
 + 2.16
µ
F, 
and 
A
UTO
. The line impedance of each port is based on the size of the network. Default is
 600 
OHMS
.
I
NTERFACES
 (FXS) > C
ONFIG
 > M
SG
 I
ND
This is better referred to as On-Hook Message Waiting. When this is set to 
E
NABLE
,
 talk path is always 
open, even in On-Hook conditions, in order for these FSK message tones to pass through. Default is 
D
ISABLE
. Enabling on-hook message waiting will allow message lamp usage but will cause a lower 
on-hook voltage. Disabling this feature will allow higher on-hook voltage but will not allow on-hook 
messaging other than caller ID.
I
NTERFACES
 (FXS) > C
ONFIG
 > B
ATT
 M
ODE
Configures the on-hook battery voltage. For most IAD installs, the FXS loop is short with 6 to 7 V present 
on tip / ring. To reduce power dissipated during off-hook conditions, the battery is lowered for short loop 
lengths. When set to 
A
UTO
 S
WITCH
, the IAD uses a higher on-hook battery voltage (48-52 V). When 
off-hook, it automatically switches to low battery (24-26 V) to minimize power dissipation. When set to 
L
OW
 B
ATTERY
 
mode, the higher battery is not used and the voltage is a constant 26 V even while on-hook. 
The tip/ring voltage is reduced to 26 V when using the 
L
OW
 B
ATTERY
 mode.
I
NTERFACES
 (FXS) > C
ONFIG
 > F
WD
 D
ISC
 T
IMER
Specifies the interval of battery removal during a forward disconnect state. Choices are 
F
OLLOW
 S
WITCH
 
(default), 
500
MS
750
MS
1000
MS
, and 
2000
MS
.   When using ATM mode, there is an additional choice of 
I
GNORE
 S
WITCH
. If the timer is set to 
F
OLLOW
 S
WITCH
, the Total Access 6XX will follow the switch at all 
times; this is normal operation. If a time period has been selected, the Total Access 6XX will remove 
battery for the specified time period OR as long as the switch requests battery removal, whichever is 
longer. For example, if the timer expires but the switch continues to request battery removal, the Total 
Access 6XX will follow the switch and continue to remove battery. For ATM mode, if the timer is set to 
I
GNORE
 S
WITCH
, the IAD will never remove battery.
I
NTERFACES
 (FXS) > C
ONFIG
 > T
ANDEM
Sets the port to use E&M signaling on the T-Span and either loop start or ground start supervision on the 
analog 2-wire interface. To access submenus for this item, use the arrow keys to scroll to the 
T
ANDEM
 
column for the corresponding module, and then press 
<E
NTER
>
.
I
NTERFACES
 (FXS) > C
ONFIG
 > T
ANDEM
 > C
ONVERSION
 M
ODE
Sets the port to either 
L
OOP
 S
TART
 or 
G
ROUND
 S
TART
 mode. Default is 
L
OOP
 S
TART
.
I
NTERFACES
 (FXS) > C
ONFIG
 > T
ANDEM
 > S
UPERVISION
Sets the supervision method used to either 
I
MMEDIATE
 or 
W
INK
. Default is 
I
MMEDIATE
.