Avaya S8100 Manuale Utente

Pagina di 408
1
Install and cable a G600 cabinet
Install and wire telephones and other equipment
S8100 Installation and Upgrades
105
November 2003
DS1 tie trunks between collocated systems
Two DS1 Tie Trunk circuit packs can exist in collocated systems. A DS1 Tie Trunk circuit pack in 1 
system can connect to a DS1 tie trunk in another system. Use a C6D cable if the distance is less than 
50 feet (15.24 m). If the distance is greater than 50 feet (15.24 m), use a C6E cable.
NOTE:
The maximum distance between cabinets is 1310 feet (399 m).
DS1 tie trunks using T1 channel-service unit
 on page 105 shows a DS1 tie trunk connected to 
an external T1 channel-service unit (CSU). An enhanced 120A2 integrated channel-service unit (ICSU) 
can be used in place of an external T1 CSU. The CSU or ICSU interfaces the DS1 tie trunks with the 
1.544-Mbps digital facility. Contact your Avaya representative for maximum cabling distances.
Figure 28: Typical connections to channel-service unit
3- and 4-pair modularity
 on page 106 shows 3- and 4-pair modularity from the port circuit 
pack to the voice or data terminal. Most terminals connect to an information outlet (modular jack) 
installed at the work location.
Figure notes
1
To DS1 Tie Trunk circuit pack
2
C6C cable – If distance is over 50 feet (15.24 m), 
use C6E cable.
3
External T1 CSU or 120A2 ICSU
4
Tip (T)
5
Ring (R)
6
Tip 1 (T1)
7
Ring1 (R1)
8
1.544-Mbps T1 interface
9
To T1 carrier