1 Install and cable a G600 cabinet
Connect modem to telephone network
134
S8100 Installation and Upgrades
November 2003
Trunk/auxiliary field: telephone used for emergency transfer and as normal extension
1
Connect a pair of wires between the -48V and GRD terminals on the yellow emergency transfer 
row/connecting block to the EM TRANS RELAY PWR terminal.
2
Connect CO trunk leads from the purple field to the TC terminals on the yellow emergency 
transfer row/connecting block for each trunk.
3
Connect CO trunk leads from the green field to the TK terminals on the yellow emergency 
transfer row/connecting block for each trunk.
4
Connect telephone leads from the purple analog line board row/ connecting block to the LC 
terminals on the yellow emergency transfer row/connecting block for each telephone.
5
Connect ST leads on the yellow emergency transfer row/connecting block for each emergency 
transfer telephone to the ST terminal appearance in the purple trunk/auxiliary field.
6
Connect the ST leads from the terminal in 
 to the assigned terminal in the blue or white 
station distribution field.
Telephone installation
1
Connect the telephone to the information outlet.
2
Install patch cords/jumper wires between the system side and the station side of the station 
distribution field on the MDF.
Connect modem to telephone network
1
Cross-connect the network jack on the modem to the network interface (via a 103A or modular 
wall jack). See 
 on page 134 for the pinout.
 
Table 22: Pinout of network jack
Pin number
Signal
1
Unused
2
Tip
3
Ring
4
Unused