16.5
A/D Conversion Accuracy Definitions
This LSI's A/D conversion accuracy definitions are given below.
 
Resolution
The number of A/D converter digital output codes
 
Quantization error
The deviation inherent in the A/D converter, given by 1/2 LSB (see figure 16-4).
 
Offset error
The deviation of the analog input voltage value from the ideal A/D conversion characteristic
when the digital output changes from the minimum voltage value 0000000000 to 0000000001
(see figure 16-5).
 
Full-scale error
The deviation of the analog input voltage value from the ideal A/D conversion characteristic
when the digital output changes from 1111111110 to 1111111111 (see figure 16-5).
 
Nonlinearity error
The deviation from the ideal A/D conversion characteristic as the voltage changes from zero to
full scale.  This does not include the offset error, full-scale error, or quantization error.
 
Absolute accuracy
The deviation between the digital value and the analog input value.  Includes offset error, full-
scale error, quantization error, and nonlinearity error.