Table 16-3 A/D Conversion Time (Single Mode)
CKS = 0
CKS = 1
Item
Symbol
Min
Typ
Max
Min
Typ
Max
A/D conversion start delay time t
D
6
9
4
5
Input sampling time
t
SPL
31
15
A/D conversion time
t
CONV
131
134
69
70
Note:
All values represent the number of states.