6.
6.
6.
6.    Functions
Functions
Functions
Functions    
 
  There are two parameters lists, one for the F-functions and one for the CF-functions. 
These functions control the indicator. The parameters of each function are stored in 
non-volatile memory, and are not lost even if power is turned off or cut off. 
F-functions: 
These parameters can always be changed and are used for internal settings. 
CF-functions:  If you accept a certificated approval of the weighing instruments, the CAL 
cover (rear panel) must be sealed. Therefore, accepting this approval, the 
parameters of the CF-function can not be changed. 
 
6.1.
6.1.
6.1.
6.1.     Changing the Function Settings
Changing the Function Settings
Changing the Function Settings
Changing the Function Settings    
To enter the function settings, do either of the following.   
1.  When the display is off, press the 
ON/OFF
 key while pressing the 
+/-
 key. 
2.  When in the weighing mode, press both the 
+/-
 and 
ON/OFF
 keys at the same time. 
When you are in the function setting, f00 will be displayed. 
Operating Item 
Step  1 
Select an item using the 
0
 - 
9
 keys. 
ENTER
 key 
The key to display a parameter of 
the selected item. 
Proceed to step 2. 
ESC
 key 
To end function setting and enter 
the weighing mode. 
CAL
 key 
The key to exchange F-functions 
and CF-functions. 
 
Operating parameter 
Step  2 
Select a parameter using the 
0
 - 
9
 keys. 
ENTER
 key 
The key to store a parameter 
and return to step 1.   
ESC
 key 
The key to return step 1 
without changing the 
parameter. 
CLEAR
 key 
Change the display as default 
value.(Type1) 
 
Change sub item.(Type2, Type3) 
 
 
Type2 and Type3 are indicated in the 
parameter table. 
 
Exit function setting 
Press 
ESC
 key to go to the weight display when item number is displayed. 
6. Functions 
Weighing 
Weighing 
+/
+/
+/
+/-
--
-
NET/GROSS 
PRINT
ENTER
PRINT 
ENTER
PRINT 
ENTER
PRINT
ENTER
TARE
ESC
0
0
+/
+/
+/
+/-
--
-
NET/GROSS
PRINT 
ENTER