Siemens XT55 ユーザーズマニュアル

ページ / 20
XT55 AVL Software Instructions User’s Guide 
Confidential/Preliminary 
s
 
m
o
 
b
 
i
 
l
 
e
 
XT55_avl_ug_V01 
Page 17 of 20 
15.03.2004 
$PSRF112, 
value, 
*XX 
 
 
Parameter description: 
value:    
//configure history function 
 
 
Defined values 
  1 
//enables 
history 
  2 
//disables 
history 
*XX 
 
//CheckSum has to be calculated. 
Example 1:  
$PSRF112,1*38 
This command enables the history function. The module XT55 records every 180 
seconds if the vehicle is driving faster than 10 km/h. 
The settings 180 sec. and 10km/h are predefined parameters. 
Example 2:  
$PSRF112,2*3B 
This command disables the history function. No data will be saved in the history. 
 
 
 
Commands build in the alarm function 
$PSRF112, 
value, 
key_number, 
phone_number 
*XX 
 
 
Parameter description: 
value:    
 
//configure the download procedure 
 
 
 
Defined values 
 
 
 
10 //enables key configuration 
 
 
 
11 //disables key configuration 
 
 
 
12 //displays key number 
key_number  
//determine the alarm key (1,2 possible) 
phone_number  
//set the authorized telephone number 
*XX  
 
//CheckSum has to be calculated.  
Example 1:  
$PSRF112,10,2,012345678 *02 
This command enables key configuration as well the predefined RMC protocol is 
send to the authorized telephone number (012345678) in case of an alarm on the 
key 2. 
Example 2:  
$PSRF112,11,2*17 
This command disables the key (2) configuration. 
Example 3:  
$PSRF112,12,2*14 
This command displays the settings of given key number (2).  
The received format is: $alarm key (2): phone: 012345678, protocol: RMC 
 
Command for internal test 
$PSRF111, 
value,  
*XX 
Parameter description: 
value:    
//commands overview 
 
 
Defined value 
 
 
//overview of all implemented test commands 
*XX  
//CheckSum has to be calculated. 
 
Example 1:  
$PSRF111,0*3A