HP (Hewlett-Packard) 50091 1-002 ユーザーズマニュアル

ページ / 118
HP StorageWorks 2000 G2 Modular Smart Array Reference Guide
79
connUnitTable
Includes the following objects as specified by the FA MIB2.2 Spec
connUnitId
Unique identification for this 
connectivity unit
Total of 16 bytes comprised of 8 
bytes of the node WWN or similar 
serial number-based identifier (for 
example, 1000005013b05211) with 
the trailing 8 bytes equal to zero
connUnitGlobalId
Same as connUnitId Same 
as 
connUnitId
 
connUnitType
Type of connectivity unit 
storage-subsystem[11]
connUnitNumports
Number of host ports in the 
connectivity unit
Number of host ports
connUnitState
Overall state of the connectivity unit  online[2] or unknown[1], as 
appropriate
connUnitStatus
Overall status of the connectivity unit  ok [3], warning[4], failed[5], or 
unknown[1], as appropriate
connUnitProduct
Connectivity unit vendor’s product 
model name
Model string
connUnitSn
Serial number for this connectivity 
unit
Serial number string
connUnitUpTime
Number of centiseconds since the 
last unit initialization
0 at startup
connUnitUrl
Same as systemURL
Same as systemURL
connUnitDomainId
Not used; set to all 1s as specified by 
the FA MIB2.2 Spec
0xFFFF
connUnitProxyMaster
Stand-alone unit returns yes for this 
object
yes [3] since this is a stand-alone unit
connUnitPrincipal
Whether this connectivity unit is the 
principal unit within the group of 
fabric elements. If this value is not 
applicable, returns unknown.
unknown[1]
connUnitNumSensors
Number of sensors in the 
connUnitSensorTable
33
connUnitStatusChangeTime
Same as statusChangeTime Same 
as 
statusChangeTime
 
connUnitConfiguration
ChangeTime
Same as 
configurationChangeTime
 
Same as 
configurationChangeTime
 
connUnitNumRevs
Number of revisions in the 
connUnitRevsTable
16
connUnitNumZones
Not supported
0
connUnitModuleId
Not supported
16 bytes of 0s
connUnitName
Settable: Display string containing a 
name for this connectivity unit
Default: Uninitialized Name
connUnitInfo
Settable: Display string containing 
information about this connectivity 
unit
Default: Uninitialized Info
connUnitControl
Not supported
invalid[2] for an SNMP GET 
operation and not settable through 
an SNMP SET operation.
Table 10
FA MIB 2.2 objects, descriptions, and values (continued)
Object
Description
Value