HP (Hewlett-Packard) 50091 1-002 ユーザーズマニュアル

ページ / 118
80
SNMP reference
connUnitContact
Settable: Contact information for this 
connectivity unit 
Default: Uninitialized Contact
connUnitLocation
Settable: Location information for this 
connectivity unit 
Default: Uninitialized Location
connUnitEventFilter
Defines the event severity that will be 
logged by this connectivity unit. 
Settable only through SMU. 
Default: info[8]
connUnitNumEvents
Number of events currently in the 
connUnitEventTable
Varies as the size of the Event Table 
varies
connUnitMaxEvents
Maximum number of events that can 
be defined in the 
connUnitEventTable
400
connUnitEventCurrID
Not supported
0
connUnitRevsTable
Includes the following objects as specified by the FA MIB2.2 Spec
connUnitRevsUnitId
connUnitId
 of the connectivity unit 
that contains this revision table
Same as connUnitId 
connUnitRevsIndex
Unique value for each 
connUnitRevsEntry
 between 1 
and connUnitNumRevs
See 
connUnitRevsRevId
Vendor-specific string identifying a 
revision of a component of the 
connUnit
String specifying the code version. 
Reports “Not Installed or Offline” if 
module information is not available.
connUnitRevsDescription
Description of a component to which 
the revision corresponds
See 
connUnitSensorTable
Includes the following objects as specified by the FA MIB2.2 Spec
connUnitSensorUnitId
connUnitId
 of the connectivity unit 
that contains this sensor table
Same as connUnitId 
connUnitSensorIndex
Unique value for each 
connUnitSensorEntry
 between 
1 and connUnitNumSensors
See 
connUnitSensorName
Textual identification of the sensor 
intended primarily for operator use 
See 
connUnitSensorStatus
Status indicated by the sensor 
ok[3], warning[4], or failed[5] as 
appropriate for FRUs that are 
present, or other[2] if FRU is not 
present.
connUnitSensorInfo
Not supported
Empty string
connUnitSensorMessage
Description the sensor status as a 
message 
connUnitSensorName
 followed 
by the appropriate sensor reading. 
Temperatures display in both Celsius 
and Fahrenheit; for example, CPU 
Temperature (Controller Module A): 
48C 118F). Reports “Not installed” 
or “Offline” if data is not available.
connUnitSensorType
Type of component being monitored 
by this sensor 
See 
connUnitSensor
Characteristic
Characteristics being monitored by 
this sensor
See 
Table 10
FA MIB 2.2 objects, descriptions, and values (continued)
Object
Description
Value