Table 6-1    
Troubleshooting the EDA
Problem
Cause
Solution
EDA does not turn 
on.
Lithium-ion battery 
not charged.
Charge or replace the lithium-ion battery in the EDA.
Lithium-ion battery 
not installed 
properly.
Install the battery properly. Se
System crash.
Perform a warm boot. If the EDA still does not turn on, perform 
a cold boot. See 
Rechargeable 
lithium-ion battery did 
not charge.
Battery failed. 
Replace battery. If the EDA still does not operate, perform a 
warm boot, then a cold boot. Se
EDA removed from 
cradle while 
battery was 
charging. 
Insert EDA in cradle. The standard capacity battery (1900 mAh) 
fully charges in less than four hours. The extended capacity 
battery (3800 mAh) fully charges in less than eight hours.
Cannot see 
characters on 
display.
EDA not powered 
on.
Press the Power button.
During data 
communication, no 
data transmitted, or 
transmitted data was 
incomplete.
EDA removed from 
cradle or 
disconnected from 
host computer 
during 
communication.
Replace the EDA in the cradle, or reattach the communication 
cable and re-transmit.
Incorrect cable 
configuration.
See the system administrator.
Communication 
software was 
incorrectly 
installed or 
configured.
Perform setup. Refer to the MC70 Integrator Guide for details.
No sound.
Volume setting is 
low or turned off.
Adjust the volume. See 
.