Alliance Laundry Systems TMB795C ユーザーズマニュアル

ページ / 63
Gas Requirements
39
M414905
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
High Altitude Burner Orifice Sizing
For proper operation at altitudes above 2000 feet 
(610 m), the gas burner orifice size must be reduced to 
ensure complete combustion. Refer to Table 6.
For CE models, consult local gas supplier. 
Table 6 
Model
Gas
Altitude
Burner Orifice
New Rate
feet
meters
No. inches mm Quantity Part Number
(Btu/hr.)*
50 Pound
Natural Gas
2001-6000
610-1830
28
0.1405
3.6
2
M401014
110,400
6001-8000
1831-2440
29
0.1360
3.4
M400997
100,800
8001-10,000
2441-3050
30
0.1285
3.3
M401021
91,200
L.P. Gas 
2001-4000
610-1220
44
0.0860
2.2
M401011
110,400
4001-6000
1221-1830
45
0.0820
2.1
M401027
100,800
6001-8000
1831-2440
46
0.0810
2.1
M401003
91,200
8001-10,000
2441-3050
47
0.0785
2.0
M400999
81,600
75 Pound
Natural Gas
2001-4000
610-1220
29
0.1360
3.4
3
M400997
151,800
4001-8000
1221-2440
30
0.1285
3.3
M401021
138,600
8001-10,000
2441-3050
31
0.1200
3.0
M401017
125,400
L.P. Gas 
2001-4000
610-1220
45
0.0820
2.1
M401027
151,800
4001-6000
1221-1830
46
0.0810
2.1
M401003
138,600
6001-8000
1831-2440
47
0.0785
2.0
M400999
125,400
8001-10,000
2441-3050
48
0.0760
1.9
M401001
112,200
F75
Natural Gas
2001-4000
610-1220
23
0.1540
3.9
3
M401020
197,800
4001-6000
1221-1830
25
0.1495
3.8
M402997
180,600
6001-8000
1831-2440
27
0.1440
3.7
M400998
163,400
8001-10,000
2441-3050
29
0.1360
3.4
M400997
146,200
L.P. Gas 
2001-4000
610-1220
42
0.0935
2.4
M403017
197,800
4001-6000
1221-1830
43
0.0890
2.3
M406184
180,600
6001-8000
1831-2440
44
0.0860
2.2
M401011
163,400
8001-10,000
2441-3050
45
0.0820
2.1
M401027
146,200
* Btu/hr. derate of 4% per 1000 feet (305 meters) of altitude.