4-3 Start-up 
Use the following procedure to start the dryer: 
1. 
Turn on the disconnect switch in the power drop, close the slide gate at the bottom of 
the drying hopper. 
2. 
Close the slide gate at the bottom of the drying hopper. 
3. 
Fill the drying hopper with material. 
4. 
Turn the ON/OFF switch to “ON” to energize the display panel and turn on the 
solenoid and the heater. 
5. 
Use the Up Arrow and Down Arrow buttons to set the process set point on the 
temperature controller. 
Note:  Consult the resin manufacturer for the recommended drying temperature. 
6. 
Press the Mode button one time to make sure the controller’s Run/Stop parameter is 
set to “RUN.” 
7. 
Use the Up Arrow or Down Arrow button to change the value to “RUN.” 
8. 
Press the Mode button to begin operation. 
9. 
After the proper pre-drying time for the initial hopper fill has elapsed, fully open the 
drying hopper slide gate.  
Note:   To allow proper residence time during continuous processing, maintain the 
material level in the hopper at the midpoint of the air trap assembly. 
4-4 Shut-down 
Use the following procedure to shut down the dryer: 
1. 
When processing is complete, close the hopper slide gate and shut down any in-line 
companion equipment. 
2. 
Lower the process temperature controller set point to a value of 100º Fahrenheit. 
3. 
Allow at least one minute of run time so that the compressed air continues to flow 
through the unit and cool down the heating components. 
4. 
Turn the On/Off switch to “Off.” 
5. 
If needed, empty the drying hopper. 
6. 
For maintenance or a long-term shutdown, open the electrical disconnects at the dryer 
and at the power drop.